Is HVAC cleaning really needed?
- inspectorjulie
- 2 days ago
- 1 min read

Spore Type | Eurofins HVAC (5/6) Pre-cleaning | EMSL HVAC (5/19) Post-cleaning |
Aspergillus/Penicillium | ND | ND |
Cladosporium | 400 spores/m³ | ND |
Myxomycetes | 400 spores/m³ | 33 spores/m³ |
Basidiospores | ND | 33 spores/m³ |
Ascospores | ND | 33 spores/m³ |
Chaetomium | 13 spores/m³ | ND |
Hyphal Fragments | 53/m³ | ND |
Total Spores | 840 spores/m³ | 100 spores/m³ |
I couldn't say what was stuck to the coin (visible with my borescope) in the supply ducting in this bedroom pre-cleaning. I took an air sample within 5 feet of the register in this room and one in the return ducting near the HVAC unit.
Even though I used two different labs you can see before and after results in the HVAC return ducting above was helpful. What changed in the bedroom was a small drop in Cladosporium and both Basidiospores and Myxomycetes showed up post cleaning where they were not found in the pre cleaning test.
Sometimes a different lab, different analyst, or even slight changes in where or how the air sample was taken can pick up new things.
These spores might have always been there — just below detection limits last time.
It is also possible that with cleaning, the spores were dispersed.